Homelab · Property Network

Burying Ethernet Between Buildings: The 100 m Limit and Doing Copper Right

An Ethernet cable in a trench is the oldest building link there is, and for runs under 300 feet it remains a perfectly good one, with conditions. The cable must be outdoor-rated, the total run must respect a hard 100-meter limit that includes the patch cords at both ends, and the install must handle the electrical reality of connecting two buildings with a copper wire. This guide covers each of those, plus the boundary where fiber takes over.

Published Nov 25, 2026

The 100-meter rule, measured correctly

The Ethernet standard allows a 100-meter channel: up to 90 meters of fixed cable plus up to 10 meters of patch cords combined at both ends. Two measurement traps catch people. First, the run is measured along the route the cable actually takes: down the wall, across the yard, up the far wall, and along to the switch, not the straight-line distance between buildings. A 250-foot gap between buildings routinely becomes a 290-foot cable route. Second, the patch cords count. Budget the whole path before you dig, and if the real total is anywhere near 328 feet, stop and read the fiber guide instead; fiber has no such limit and costs barely more. Within the limit, cable choice is simple: Cat6a carries 10 Gbps the full 100 meters, while Cat6 manages 10 Gbps only to about 55 meters (both do gigabit the whole way). For a buried run you will not want to redo, Cat6a is the sensible default.

Cable and conduit choices

Buried cable must be rated for it: look for direct-burial or CMX outdoor cable, which has a UV-resistant jacket and, in the better versions, a gel-filled or water-blocked core that keeps moisture out of the pairs for decades. Ordinary indoor cable in the ground fails within a few seasons as its jacket cracks and the pairs wick water. The conduit decision is about the future. Direct burial is faster and cheaper today. Cable in conduit (inexpensive PVC, or a continuous HDPE duct) costs a little more and some digging care, and in exchange the cable can be replaced or joined by a fiber later by pulling, not digging. If the trench is open anyway, conduit is the grown-up choice. Depth rules vary by location and method: low-voltage conduit is commonly buried around 18 inches down and direct-burial cable around 24 inches, but local code governs, and a call to your local permitting office or a check of the adopted code is part of doing this right. Whatever the depth, lay a detectable warning tape a few inches above the run, and photograph the open trench with measurements before you fill it.

The electrical part: grounding and surge

A copper cable between two buildings electrically bonds them, and buildings on separate services or panels can sit at slightly different ground potentials. That difference can drive small currents through your cable’s shield and, in faults or nearby lightning strikes, much larger ones. Three practices keep copper safe. Use shielded cable and connectors for the outdoor run, with the shield bonded at the house entry. Install an Ethernet surge protector where the cable enters each building (the Ubiquiti ETH-SP-G2 at about $12.50 is the standard part), each bonded to that building’s ground with a short, direct wire. And never run the outdoor cable into a switch without that protector in line. The lightning and grounding guide in this series explains the physics in plain language, including why fiber deletes the entire problem by carrying light instead of current.

Prices are editorial estimates, checked against retailer listings on the date stated on the page, and change often — the links open current listings where you can verify price and availability. Some links may earn a commission at no cost to you — see the disclosure page.

When copper is right, and when it is not

Copper is right when the measured route is comfortably under 300 feet, the two buildings share one electrical service (a detached garage on the house’s panel is the classic case), and you install the surge protection at both ends. It is the wrong tool when the run pushes the 100-meter limit, when the buildings have separate services and ground systems, or when the path crosses open ground that takes lightning strikes. In those cases the same trench with a pre-terminated fiber cable costs roughly the same, removes the distance ceiling, and removes the electrical connection entirely. The fiber guide in this series has a complete worked parts list.

A short install sequence

Measure the route and total the channel length including patch cords. Call 811 (in the US) to have underground utilities marked before any digging; that step is free and not optional in practice. Dig or trench to your code depth, lay conduit or cable with gentle bends (no kinks; Ethernet hates tight radius), pull the cable with a spare pull string in conduit, terminate or use pre-terminated outdoor assemblies, fit surge protectors at both entries with short ground bonds, and test with a cable tester for wire map plus a real gigabit link and speed test at the far switch. Then, and only then, backfill, with the warning tape above the run as you go.

References

Frequently asked questions

Can I run ordinary indoor Ethernet cable underground in conduit?

It will work at first and fail early. Indoor jackets are not waterproof or UV-rated, and conduit underground always ends up with water in it. Use outdoor or direct-burial rated cable, gel-filled for direct burial, even inside conduit.

My buildings are 320 feet apart. Can I stretch the limit a little?

No. The 100-meter (328-foot) channel includes your patch cords and the vertical runs at both ends, so a 320-foot building gap is already over. This is the textbook case for fiber, which covers that distance trivially.

Do I really need surge protectors at both ends?

Yes. Each building entry is where a surge wants to get into your equipment, and the protector only helps the building it is bonded to. One at each end, each with a short ground bond, is the correct install and costs about $25 total.

How deep does the cable need to be?

It depends on your local code and method; around 18 inches for low-voltage conduit and 24 inches for direct-burial cable are common figures. Verify locally, mark utilities through 811 first, and add warning tape above the run.

Related guides