Free tool · Homelab

Homelab Rack Planner

Stack the gear you plan to buy into a virtual rack before you spend anything. The planner totals the four budgets every rack has — space in rack units, power in watts, heat in BTU per hour, and your switch's PoE budget — and warns you while the fix is still free.

DeviceUWattsPoE WQty

Your rack, top to bottom

Watts are typical running draws, not power-supply ratings — a 300W PSU in a mini PC does not mean 300W from the wall. PoE devices are counted once in the total power (their watts arrive through the switch) and again against the PoE budget, which is the number that decides whether the switch can feed them.

How to use the numbers

Space is the budget people blow first: the starter rack above fills 8U of a 12U rack before a second node, a bigger UPS or the 10GbE switch you will want next year. Buying one rack size up is the cheapest upgrade in the whole build — our rack guide covers the depth trap that matters more than the U count.

Power here is running draw, and it feeds two other numbers: the Homelab Power Cost Calculator turns the same watts into UPS runtime, and our running-costs guide shows what 24/7 watts do to a year of electricity bills.

Heat is the budget nobody plans: every watt becomes 3.412 BTU/hr in the room. Under roughly 1,000 BTU/hr a cracked door copes; above it, a closet rack needs a deliberate airflow path — the cooling and noise guide works the numbers.

PoE budget is a property of the switch, not the rack: add up the PoE column and compare it with the budget in the switch's spec sheet before you buy either. The managed switch guide explains why two switches with the same port count can have budgets 100W apart.

Frequently asked questions

What counts as a rack unit (U)?

One U is 1.75 inches (44.45mm) of vertical rack space. Gear is sold by how many U it occupies — a typical managed switch is 1U, a 2U UPS is two. This planner adds up the U of everything rack-mounted and compares it with the rack size you pick; shelves count too, because a mini PC on a shelf still spends the shelf's U.

Why does the planner count PoE devices in the total watts?

Because their power really is spent in the room — it just travels through the switch first. An access point drawing 13W of PoE heats the room by the same 13W as a 13W plug-in device, and the switch has to supply it on top of its own draw. The planner counts each watt once in the total, and separately checks the PoE total against your switch's budget.

How much heat does a homelab rack actually make?

Essentially all of its power draw, converted at 3.412 BTU per hour per watt. The default starter rack here — switch, NAS, mini PC, UPS, two access points, two cameras — makes about 553 BTU/hr, roughly a small space heater on low. Past about 1,000 BTU/hr in a closed closet, airflow stops being optional.

Does a 10-inch mini rack change the math?

The U math is identical — mini racks come in the same U sizes (4U, 8U, 12U). What changes is width and depth: 10-inch racks fit mini PCs, small switches and single-board computers, and most are only about 200–260mm deep, so full-size 19-inch gear and deep servers do not fit at all. Check our rack guide before buying one for gear you already own.

Related guides