Home Security · Alarms

Local Smoke & CO Alarms in Home Assistant

Smoke and carbon monoxide alarms are the one category where this site’s usual advice runs in a specific order: the listed alarm on the ceiling does the life-safety job, and the smart layer’s job is to make sure you hear about it — when you are in the garden, upstairs with headphones on, or away from home entirely. This guide covers the local-first ways to connect alarms to Home Assistant: connected alarms that report over Z-Wave, listener modules that hear the alarms you already own, and the automations that turn a detector event into lights, sirens, and phone alerts. Nothing here replaces a listed alarm, and the guide says so wherever it matters.

Published Nov 21, 2026

The rule that comes before all the technology

Start with placement and listing, because no integration fixes either. Alarms belong inside every bedroom, outside each sleeping area, and on every level of the home, and carbon monoxide alarms belong near sleeping areas and fuel-burning appliances — the placement guidance published by fire-safety bodies such as the NFPA is the reference to follow for your layout, along with your local code. Detectors also expire: smoke alarms are replaced after ten years, CO sensors have their own shorter service lives, and a smart notification from an expired sensor is a notification about nothing. Interconnection matters as much as placement. When one alarm sounds, all of them should sound, so a basement event is audible in a bedroom. Modern alarms do this with a wired interconnect or a wireless interconnect of their own, entirely independent of any smart home system.

With that foundation stated, the smart layer has a clear and limited job description. It listens for alarm events and adds reach: a phone notification when nobody is home, lights that come on along an escape path, a siren or announcement in a part of the house where the alarm is hard to hear, and a log that shows when an alarm sounded and which one it was. It never sits between a detector and its sounder, and a Home Assistant outage must never silence an alarm. Every option below respects that boundary — the alarms sound on their own, and the house adds its voice afterwards.

Option one: connected alarms that report for themselves

The cleanest smart setup is an alarm that is both a listed detector and a network device. The established example in the Z-Wave world was First Alert’s ZCOMBO, a combined smoke and CO alarm that reported alarm state, battery, and test events to the hub. One fact needs stating plainly for anyone shopping today: the ZCOMBO has been discontinued. Listings that remain are old stock, and an alarm’s age matters — a detector that has sat in a warehouse has already spent part of its service life. Owners who already run ZCOMBO units should keep using them until their replacement date and simply plan the successor now.

The successor is the First Alert SMCO410, which carries the same concept forward — a combined smoke and CO alarm with a Z-Wave radio — and moves to a sealed ten-year battery, so there are no annual battery swaps for the life of the unit. Treat it the way you would treat the older model in Home Assistant: pair it with your Z-Wave controller, confirm that smoke, CO, battery, and heartbeat entities appear, and run the alarm’s own test button to watch the event arrive before you build automations on it. Because the unit is new to the market, check the manufacturer’s listing for current pricing and availability rather than relying on early retailer pages.

Option two: alarm listener modules for alarms you already own

Many houses already have good interconnected alarms, and replacing all of them to gain notifications is poor arithmetic. That is the case listener modules exist for. An audio listener is a small device mounted within a few inches of an existing alarm; it is trained on the standard alarm sound patterns — the temporal-three pattern for smoke and the temporal-four pattern for carbon monoxide — and reports to the hub when it hears one. The listed detector stays exactly where it was, untouched and fully in charge of sounding; the listener only reports what it hears. Because one listener hears one alarm, the layout is one listener per alarm you want identified, placed close enough that it cannot confuse the neighbor’s alarm with its own.

A second kind of listener suits hardwired systems: a bridge module that connects to the interconnect wire of a wired alarm circuit and reports when the circuit signals. When any wired alarm on the circuit sounds, the interconnect line carries the event, and the bridge passes it to the hub over a low-power mesh radio. This is the tidiest route for houses with wired interconnected alarms, because one bridge covers the whole circuit’s alarm event — although it reports the circuit, not the individual room, so the notification says “the alarms are sounding” rather than naming the bedroom. Either way, the buying rule is the same: choose a listener whose radio matches the mesh you already run, and confirm it reports both the smoke and CO patterns before relying on it.

Bringing the events into Home Assistant

Connected alarms and Z-Wave listeners arrive through the Z-Wave JS integration, which is this site’s standard Z-Wave stack; the pairing and controller setup live in the Z-Wave JS UI guide. Once a device is included, name it for its room immediately — “Upstairs hall smoke and CO” is a name a notification can use at 3 a.m.; “Node 47” is not. Check that the device exposes separate smoke and CO alarm entities or binary sensors, a battery level, and ideally a heartbeat or periodic wake-up you can watch. Then test properly: use the alarm’s test button, confirm the right entity changes in Home Assistant, and confirm it clears afterwards. A test that only checks pairing is not a test of the path the real event will take.

Two reliability habits matter more than any automation you will write. First, watch for silence: a battery alarm that stops reporting should itself trigger a notification, because a dead detector reports nothing and looks exactly like a quiet house. Home Assistant’s device availability and last-seen times make this a simple automation. Second, keep the alarm system’s own interconnection as the primary alert and treat the hub as additive — if the server is down for maintenance, the alarms still sound everywhere they should, and only the phone notification is missing.

Automations that earn their place

The notification automation is the core of the whole project: on a smoke or CO event, notify every household phone immediately, with the room named, using a critical or time-sensitive alert class so it sounds through silent modes where the platform allows it. Add the house itself as a second channel — lights on along the hall and stairs, and any smart speakers announcing the alarm — because phones get left in other rooms and alarms happen at night. A third, quieter automation handles the unglamorous events: low battery, end-of-life, and a device that has not checked in for longer than its normal interval, each routed as a maintenance reminder rather than an emergency alert, so the household learns that a loud alert always means the real thing.

Resist two tempting extras. Do not automate unlocking doors or opening garages on an alarm event; an alarm is precisely when you do not want the house making security decisions unsupervised. And do not silence or reset anything remotely as an automation — investigation is a human job. The alarm pages of this site’s security series, starting with alarm sensors, sirens and keypads and the local alarm system guide, cover the wider system these detectors report into; smoke and CO sit alongside it as their own category, with their own rules, and that separation is deliberate.

What to buy, in order

If your alarms are due for replacement anyway, buy current listed interconnected alarms first and smart features second: the SMCO410 class of connected alarm where you want per-room reporting, or standard listed alarms plus listeners where you do not. If your alarms are mid-life and interconnected, add listener modules and spend the savings on the alarms’ eventual replacements. If your house has no interconnect and no plan to add one, fix that before any of this — a notification to your phone is a poor substitute for an alarm that wakes the person in the next room. Smart alerts supplement listed alarms; they never replace them, and a setup that keeps that order is the one worth building.

Official documentation and references

Frequently asked questions

Do smart alarms replace regular smoke and CO alarms?

No. The listed alarm on the ceiling does the detecting and sounding, and it must meet placement and interconnection guidance on its own. The smart layer only adds reach — phone notifications, lights, and a log — and it must never be able to silence or delay the alarm itself.

Is the First Alert ZCOMBO still worth buying?

It has been discontinued, so remaining listings are old stock, and a detector’s service life runs from manufacture, not from installation. Existing owners can keep using theirs until the replacement date; new buyers should look at the successor, the First Alert SMCO410, with its sealed ten-year battery.

What is an alarm listener, and where does it go?

A listener is a small module mounted within a few inches of an existing alarm. It recognizes the standard smoke and CO sound patterns and reports them to your hub, while the listed alarm stays in place doing its own job. You need one listener per alarm you want identified individually.

What happens to my alerts if Home Assistant is down?

The alarms still sound and interconnect exactly as they would with no smart home at all — that behavior never depends on the hub. You lose only the additions: phone notifications, light responses, and the event log, until the server is back.