Synology · Storage

SHR vs RAID on Synology: The Worked Examples

Synology Hybrid RAID is usually sold with one sentence — “it uses mixed drive sizes better than RAID” — and that sentence is only sometimes true. SHR is not a new RAID level. It is an automated management layer that slices each drive into size bands, builds an ordinary RAID array inside each band, and joins the results into one pool. Whether that helps you depends entirely on the shape of your drive set, and the only way to see it is to work the numbers. This guide works them, including the famous mixed-size example where SHR and RAID 5 finish in an exact tie.

Published Nov 23, 2026

The short answer

SHR is not a new RAID level — it is a management layer that slices mixed-size drives into bands, builds ordinary RAID inside each band, and wastes less space than a single classic array when drive sizes differ. With identical drives it ties plain RAID exactly; with mixed sizes it can win terabytes. Choose SHR for a home pool you will grow piecemeal, plain RAID when the array must be readable by anything else — and choose before the pool exists, because switching means rebuilding.

How SHR actually works

Start with how classic RAID treats a mixed set of drives. A RAID 5 array stripes across every drive at the size of the smallest one. In a pool of 4 TB, 4 TB and 8 TB, the array is built as if all three drives were 4 TB, and the upper half of the 8 TB drive simply never participates. That stranded capacity is the problem SHR exists to solve.

SHR solves it by cutting each drive into bands at every distinct size present in the pool. Within a band, DSM builds a conventional array with the standard redundancy rules: a band spanning two drives becomes a mirror (RAID 1), and a band spanning three or more drives becomes RAID 5 in an SHR pool, or RAID 6 in an SHR-2 pool. The bands are then joined with LVM and presented as a single storage pool. Underneath the marketing name, an SHR pool is a stack of ordinary mdadm arrays — Synology’s contribution is choosing the layout for you, and re-choosing it as drives change.

Redundancy follows the familiar levels. SHR (sometimes written SHR-1) tolerates one drive failure, like RAID 5. SHR-2 tolerates two, like RAID 6, and it needs at least four drives at creation. A pool built on a single drive and labeled SHR tolerates no failures at all — Synology’s own table lists zero for that case — so the name on a one-drive pool describes how it can grow, not any protection it currently has. One more caveat before the math: SHR is offered on specific Synology models only, and some series exclude it, so confirm it appears in your model’s Storage Manager before planning around it.

Worked example one: 4 TB + 4 TB + 8 TB — a tie

This is the example most often used to promote SHR, and worked carefully it shows the opposite of what people expect. All figures are nominal drive-label terabytes, the same basis Synology’s own RAID calculator uses; DSM displays usable space in binary units and after overhead, so the number on your screen will read lower than any figure in this section.

LayoutHow the capacity is builtUsableProtectionUnused
RAID 5(3 − 1) × smallest drive = 2 × 4 TB8 TB4 TB4 TB
SHRBand 1: first 4 TB of all three drives as RAID 5 = 8 TB. Band 2: the remaining 4 TB sits on one drive only, with nothing to mirror or parity against8 TB4 TB4 TB

Eight terabytes either way. The reason is structural: a band that exists on only one drive cannot be protected, and unprotected space is not offered as usable space. With a single oversized drive in the set, SHR has nothing extra to work with, and it gains exactly nothing over RAID 5. Any guide that quotes this drive set as an SHR win has skipped the second band.

Worked example two: 4 TB + 8 TB + 8 TB — where SHR earns its name

Now replace one of the 4 TB drives with a second 8 TB drive, which is the natural upgrade a year or two later. The band structure changes completely:

LayoutHow the capacity is builtUsable
RAID 5Still (3 − 1) × smallest drive = 2 × 4 TB — the smallest drive still sets the stripe width8 TB
SHRBand 1: first 4 TB of all three drives as RAID 5 = 8 TB. Band 2: the next 4 TB now exists on two drives, so it becomes a RAID 1 mirror = 4 TB12 TB

The upgrade added 4 TB of usable space under SHR and nothing under RAID 5. That is the whole case for SHR in one comparison: it pays off when a capacity band exists on at least two drives, and it pays nothing when every size in the pool is unique to one drive. The general rule for SHR-1 is to work band by band — for each band, usable space is the number of drives in that band minus one, multiplied by the band’s thickness — and add the bands together.

Growing a pool: the rules differ, and SHR’s are kinder

Synology’s expansion rules are where the two layouts diverge in daily life. Adding a drive to an existing SHR pool requires an empty bay, and the new drive must be either at least as large as the largest drive already in the pool, or exactly the same size as one of the existing drives. A drive of an in-between size that matches nothing cannot be added. Replacing drives to grow an SHR pool is done one drive at a time, with the pool fully repaired before the next swap. If all your drives are the same size, you must replace at least two of them with larger ones before capacity grows — one bigger drive alone adds nothing, for exactly the band reason shown above. In a mixed pool, replacements must be at least as large as the largest existing drive, and you replace the smallest drives first to unlock capacity soonest.

Classic RAID is stricter about growth. Synology’s guidance for RAID 1, 5, 6 and 10 pools is likewise to replace the smallest drive first — but capacity grows only when every drive in the array has been replaced with a larger one. Replace three of four drives in a RAID 5 pool and you have spent the money and gained nothing until the fourth swap finishes. Under SHR, the same sequence yields usable space as soon as the second replacement completes. For a home NAS that grows one drive at a time as budget allows, that asymmetry is SHR’s main practical advantage — larger than the headline capacity math.

When plain RAID is the better choice

SHR is the sensible default for a home Synology, but it is not always the right answer. If every drive is the same size and always will be, SHR and RAID 5 or 6 produce identical usable capacity, and the classic layout is the simpler, more predictable one. For performance-sensitive random workloads — virtual machines and databases are the usual examples — RAID 10 is the standard answer, and SHR has no equivalent: its bands are parity arrays, with parity write overhead, not mirrors striped together. Portability also argues for classic RAID. An SHR pool is a Synology-managed stack of arrays and volume groups; experts can assemble one under Linux, but a plain RAID 5 or 6 pool is the standard layout that third-party recovery tooling expects, and an SHR pool moved to a model that does not offer SHR is a dead end. Finally, some models simply do not offer SHR, and some environments need a named, standard RAID level for documentation or compliance reasons.

The decision you cannot revisit

DSM’s Change RAID Type feature converts a pool in place, with data preserved, but the supported list is short and closed. Within classic RAID you can move from Basic to RAID 1 or RAID 5 by adding drives, from RAID 1 to RAID 5, and from RAID 5 to RAID 6. Within the SHR family, exactly one cross exists: SHR-1 to SHR-2, in place, by adding drives — how many depends on your pool’s configuration, typically one or two, and the wizard tells you what your pool requires; the result must satisfy SHR-2’s four-drive minimum.

Everything across the family line is impossible in place. There is no conversion from RAID 5 or RAID 6 to SHR, none from SHR back to RAID 5 or 6, and no downgrade from SHR-2 to SHR-1. Crossing between the families means backing everything up, deleting the pool, recreating it the other way, and restoring. So the SHR-versus-RAID choice is effectively made once, at pool creation, for the life of that pool. Choose SHR if your drives are mixed or will grow unevenly; choose classic RAID if the set is uniform, the workload wants RAID 10, or the pool may one day need to live outside a Synology. And whichever you choose, keep the standing rule in view: neither layout is a backup. Redundancy keeps the pool online through a drive failure; it does nothing about deletion, corruption or a dead NAS, which is what the backup guide linked below is for.

Run your own drive set through it

Every worked example in this guide is someone else's drive shelf. The free NAS Storage Planner takes the exact drives you own or are pricing and returns usable capacity under SHR and each classic RAID level side by side — the tie, the win, and the wasted band, computed for your shelf instead of a hypothetical one.

Official documentation and references

Frequently asked questions

Does SHR always give more usable space than RAID 5?

No. With equal-size drives the two are identical, and with a single oversized drive they are identical too: 4 TB + 4 TB + 8 TB yields 8 TB usable under both SHR and RAID 5, because the extra 4 TB exists on one drive only and cannot be protected. SHR pulls ahead when a size band exists on at least two drives — at 4 + 8 + 8 TB, SHR gives 12 TB usable against RAID 5’s 8 TB.

How many drives does SHR-2 need?

At least four at creation. SHR-2 provides two-drive fault tolerance, equivalent to RAID 6, and its bands need enough drives to form dual-parity arrays. SHR with one-drive tolerance needs at least two drives to have any redundancy at all; a single-drive SHR pool tolerates zero failures.

Can I convert a RAID 5 pool to SHR without wiping it?

No. DSM’s in-place Change RAID Type list does not include any crossing between classic RAID and SHR, in either direction, and there is no SHR-2 to SHR-1 downgrade. The only in-place cross inside the SHR family is SHR-1 to SHR-2, which adds drives. Moving between RAID and SHR requires a full backup, recreating the pool, and a restore.

Why did replacing one drive with a bigger one add no space?

Because of the band rule. A larger replacement creates a new size band that exists on that one drive only, and space on a single drive cannot be mirrored or parity-protected, so it stays unused. In an equal-size SHR pool you must replace at least two drives with larger ones before usable capacity grows; the second replacement gives the new band a partner.

Is SHR a backup?

No. SHR is redundancy: it keeps the pool available when a drive fails. It does not protect against accidental deletion, file corruption, ransomware or the NAS itself failing, because all of those affect every copy in the pool at once. Backups are a separate system — Hyper Backup to a different device or off-site is the Synology-native route.