Generator runtime calculator
“How long will it run?” is the only generator question that matters at hour nine of an outage. Enter your generator’s size, its tank, and the load you actually expect, and this calculator estimates fuel consumption and runtime — plus the fuel you would need for a 24-hour and a 72-hour outage. It is the planning companion to the genmon guide (for standby units) and the energy hub.
Private by design. Everything on this page runs locally in your browser. Nothing you enter is uploaded or sent anywhere.
Your generator and load
Use a realistic average, not the peak: a house on a portable generator typically averages 25–50% of its capacity across a day (fridge cycling, lights, a furnace blower), even if the well pump spikes it briefly. Inverter generators sip at low load; conventional portables barely slow down — the model below reflects that.
The model, and its limits
The estimate scales fuel consumption from the generator’s rated size and your load: a gasoline engine burns roughly 0.11 gallons per hour per kilowatt at full load, and consumption falls with load — steeply for inverter models (which throttle down), shallowly for conventional portables (which run at a constant 3,600 RPM and save comparatively little at part load). Propane carries about 27% less energy per gallon than gasoline, so the same work takes roughly 1.3× the gallons (and propane tanks are rated in pounds — a 20 lb tank holds about 4.6 gallons). Diesel runs the other way, about 15% more runtime per gallon. Treat the output as a planning estimate within roughly ±20%: the manufacturer’s published runtime at 50% load, printed on the box, is the ground truth for your exact unit — if it disagrees with this page, believe the box and adjust the load percentage until they meet. The outage plan that matters is the 72-hour column: stored fuel for three days, rotated like the filament shelf wishes everything was, is what separates an inconvenience from an emergency.
- Battery sizing calculator — the silent half of backup planning.
- Generac and genmon — standby units, monitored locally.
Frequently asked questions
Why does an inverter generator run so much longer at low load?
It throttles its engine to the load; a conventional portable spins at a fixed speed to hold frequency and burns nearly its cruising fuel regardless. At a 25% average load the difference is routinely two-to-one in runtime per tank.
How much fuel should I store?
Plan from the 72-hour column, then store what your local rules and safe storage allow — for many households that is two or three 5-gallon cans, rotated into vehicles so the fuel stays fresh, plus stabilizer for anything stored past a few months.
Does propane really use more gallons?
Yes — propane holds less energy per gallon (about 91,500 BTU vs gasoline’s ~120,000), so the engine burns roughly 1.3 gallons of propane for a gallon of gasoline’s work. Propane’s compensation is storage life: it does not go stale.
Can I just run at very low load all day to save fuel?
Mostly, with one caution: prolonged very-light-load running is unkind to some engines (wet stacking in diesels; carbon in small gasoline engines under chronic light load). A daily period at a healthy load — the water heater, the dryer circuit — is good for the machine as well as the plan.