Energy-monitoring smart plugs in Home Assistant: find your vampire loads
Whole-home monitoring tells you the house used 31 kWh yesterday. A $20–25 plug on the right outlet tells you what — the ancient fridge in the garage, the entertainment stack sipping 38 watts all night, the washer that finished an hour ago. This guide covers where plug-level monitoring earns its keep, which plugs report honestly, how to feed the results into the Energy dashboard, and where the safety lines are.
Published Nov 18, 2026 · Last updated Nov 18, 2026
Start with the jobs, not the gadgets
Plug-level monitoring pays off in three specific jobs. Everything else is dashboard decoration:
- Appliance-done alerts. A washer's power draw is a perfect signature: high and variable while running, near zero when finished. A plug turns that into a "washer done" notification with no smart appliance premium — the automation is below, and it also works for dishwashers and (gas) dryers on standard outlets.
- Vampire hunting. Entertainment centers, office desks, game consoles, chargers and anything with a wall-wart draws power 24/7. Put a plug on the strip for a week, read the overnight baseline, and you have the number that decides whether a switched strip or a schedule pays back.
- One suspicious appliance. The second fridge, the dehumidifier, the space heater in the workshop — the loads you'd never justify a panel sensor for. A week of plug data converts "that fridge feels expensive" into dollars per month.
Already have whole-home monitoring? Plugs complement it, they don't duplicate it. The panel view (see our whole-home energy hardware guide) finds which circuit; plugs find which device on a shared circuit. If you have neither, start with two or three plugs on your suspects — it is the cheapest education in home energy there is.
Protocols, compared honestly
Wi-Fi with a local API (Shelly-style)
The benchmark plug reports power several times a second, exposes a local API and MQTT, and keeps working if the internet dies — Home Assistant's Shelly integration is local push, no cloud account needed. Downsides: each plug joins your Wi-Fi (fine at five plugs, a consideration at fifty), and per-plug cost is at the higher end. For measurement quality per dollar, this is the class to beat.
Zigbee plugs
Cheaper per unit, sips no Wi-Fi airtime, and most double as Zigbee routers that strengthen your mesh — a real bonus in a big house. Reporting is the variable part: some models report power changes eagerly, others on a lazy interval that smears short cycles, and accuracy at very low wattages is often optimistic. For vampire hunting and done-alerts they are usually fine; for precise per-load accounting, check the specific model's reporting behavior before buying a box of them.
What to ignore
Cloud-only plugs whose energy data lives in a vendor app with no local path into Home Assistant. If HA can't see the watts, the plug is a remote switch with a graph you can't use. Also ignore any plug that reports only cumulative kWh with no live power — done-alerts and vampire baselines both need the live number.
Accuracy: monitoring-grade, on purpose
Set expectations the same way we do for panel monitors in our Energy dashboard guide: plug data is monitoring-grade, not billing-grade. Good plugs land within a percent or two on straightforward loads and drift more on tiny or electrically ugly ones. That precision answers every question in this guide — find the vampire, price the fridge, catch the finished washer. It does not settle an argument with your utility, and a plug that disagrees with your panel monitor by a few percent is normal, not broken.
Feeding the Energy dashboard
- Add the plug's integration and confirm you have both a power sensor (W) and an energy sensor (kWh). Power alone cannot join the dashboard.
- If only power exists, create a helper: Settings → Devices & Services → Helpers → Integral sensor (Riemann sum, left method) over the power sensor, unit kWh. Give it an hour of runtime before judging the numbers.
- Open Settings → Dashboards → Energy → Individual devices and add the energy sensor. It now appears in the dashboard's per-device breakdown alongside anything your panel monitor reports.
- For daily/weekly views outside the dashboard, a
utility_meterhelper over the same energy sensor gives you clean today/this-month entities for automations and cards — and because long-term statistics are what the dashboard actually reads, leave the recorder defaults alone unless you have a reason; statistics survive even if raw history is purged.
The washer-done automation
Two small automations and one helper beat every clever single-automation attempt. A helper (input_boolean.washer_running) remembers "a cycle actually started," so the finish alert can't fire from a plug that was simply idle:
alias: Laundry — washer started
triggers:
- trigger: numeric_state
entity_id: sensor.washer_plug_power
above: 10
for: "00:01:00"
actions:
- action: input_boolean.turn_on
target:
entity_id: input_boolean.washer_running
mode: single
alias: Laundry — washer finished
description: Power drops to idle for 3 minutes after a real wash cycle
triggers:
- trigger: numeric_state
entity_id: sensor.washer_plug_power
below: 2
for: "00:03:00"
conditions:
# Only announce if it actually ran (avoid a ping every idle 3 minutes)
- condition: numeric_state
entity_id: sensor.washer_plug_energy_today
above: 0.05
- condition: state
entity_id: input_boolean.washer_running
state: "on"
actions:
- action: input_boolean.turn_off
target:
entity_id: input_boolean.washer_running
- action: notify.mobile_app_your_phone
data:
title: Washer done
message: "The wash cycle finished — time to move it to the dryer."
mode: single
Tune the numbers to your machine: the below 2 W for 3 minutes finish test fits most modern washers; an older machine that idles at 4 W needs a threshold above its idle and below its spin draw. Watch the power graph for one real cycle and set both thresholds from the trace, not from a blog post — including this one.
Safety, without fine print
- Respect the rating, continuously. A plug rated 15 A / 1800 W is rated for peaks; a resistive heater sits at that ceiling for hours, which is where marginal plugs overheat. For heaters, use a plug explicitly rated for continuous resistive loads — or monitor that circuit at the panel and don't plug it at all.
- 240 V appliances are out. Electric dryers, ovens, EV charging on 240 V — no smart plug exists for these. Panel-level monitoring is the tool.
- Never on medical or life-safety devices. No plug in the control path of anything medical, a sump pump you depend on, or a fridge whose silent failure would be dangerous — monitor-only placement, and even then think twice about a device that can switch the outlet off.
- A monitoring plug that can switch is a switch. Disable the relay's power-on state surprises: set plugs used purely for metering to restore-on and consider locking the switch entity out of casual dashboards, so nobody "tidies up" by turning off the fridge.
Plugs and monitoring we build on
Prices are editorial and change often; buttons show live prices. Some links may earn a commission at no cost to you — see the disclosure page.
The Shelly is the per-plug recommendation from this guide; the Emporia Vue is there for the other end of the same project — when plug data convinces you the panel view is worth having too, it is the monitor our whole-home hardware guide builds around.
Official documentation and references
- Shelly Plug US — official product page (ratings and specifications)
- Shelly knowledge base — Shelly Plug US
- Home Assistant documentation — Energy dashboard
- Home Assistant documentation — individual device energy monitoring
- Home Assistant documentation — utility_meter integration
Frequently asked questions
How accurate are energy-monitoring smart plugs?
Monitoring-grade, not billing-grade. A good plug (Shelly-class) is typically within a percent or two on resistive loads and a bit looser on small, weird loads like phone chargers — plenty to find a 40 W vampire or prove the old fridge costs $18 a month, not enough to dispute a utility bill. That is the same standard we hold whole-home monitors to elsewhere on this site.
Wi-Fi or Zigbee plugs for energy monitoring?
Wi-Fi plugs with a local API (Shelly is the benchmark) report fast, work without a coordinator, and each plug is its own little web server — great data, more devices on your Wi-Fi. Zigbee plugs keep the load off Wi-Fi, mesh-repeat for your Zigbee network, and are usually cheaper per plug, but reporting intervals and accuracy vary more by brand. Either is fine; pick per location, and don't mix so randomly that future-you can't remember what reports what.
Can I put a smart plug on my washer, dryer or space heater?
Washer: yes, on a plug rated for the load — most washers peak well under a plug's 15 A rating. Electric dryer: no — it is a 240 V appliance, no plug exists for it; monitor it at the panel instead. Space heaters and other resistive heating loads sit at a plug's maximum continuously, which is where cheap plugs fail — use a plug explicitly rated for it, or better, monitor at circuit level and skip the plug.
Why doesn't my plug show up in the Energy dashboard?
The Energy dashboard's individual-devices section needs an energy sensor (kWh) with the right device class and state class — a power sensor (W) alone won't appear. Most integrations provide a matching energy entity; if yours only gives power, create a Riemann-sum integral helper to convert it, wait for statistics to accumulate, then add it under Settings → Dashboards → Energy → Individual devices.
Will a smart plug save money by itself?
No — it measures; you save. The wins come from what the data triggers: finding the always-on load you didn't know about, proving which old appliance to replace, and automations like cutting a vampire strip when the TV is off. Expect the first month of measuring to find one or two loads worth more than the plug cost; after that it is maintenance, not magic.